When designing wound components with ring cores the surface area of the part is not fully defined until the winding(s) are designed. This is at odds with E core, PQ and PM core devices in which the surface area is well defined by the former and the window which we aim to fill. In ring cores space must be left for the shuttle to pass through the center of the torus even when the winding is finished. Common Ku values are around 0.25 as opposed of 0.4 for E, PQ and PM cores wound with round wire / litz windings. Ku values for cores wound with bus bars or foils may be appreciably higher.
Knowledge of the surface area of the device in advance of a full design analysis is desirable because the surface area is commonly used, in conjunction with the loss budget for the device, to analytically (i.e. without resorting to finite element analysis) estimate the temperature rise expected on the device surface in steady state under normal operation. We can then use some engineering judgement to further estimate a likely hotspot temperature in the winding center under this condition as well.
The document linked below (MathCad Prime 7 and PDF) develops an estimate for the winding dimensions without resorting to a full design process. This may be used when multiple cores are under consideration for a particular design to estimate the ballpark thermal performance of a particular core choice given some reasonable assumptions about the winding design.
Ring core temperature rise estimation MathCad 7 Format
Ring core temperature rise estimation PDF
Design Support from our resident Magnetics Designers
Bear Instruments provides attractive magnetic component solutions including full design documentation, production of samples, test, validation, on-site support and reporting as well as mass production and distribution via our selected partners. Call or email to find out how we can push your product development forward.